Îòêðûòîå Àêöèîíåðíîå Îáùåñòâî "Ìîãèëåâñêèé çàâîä "Ýëåêòðîäâèãàòåëü", Ðåñïóáëèêà Áåëàðóñü
The advanced order of production

Output power

The output power of electric motor is defined by the following conditions:

  • rated voltage indicated on the name plate at tolerance of ±10%
  • frequency of supply voltage at tolerance of ±1%
  • temperature of cooling air - up to 40°C (313K)
  • altitude up to 4300m
  • continuous duty cycle S1 according.

In case of deviation from indicated conditions the advisable output power should be defined according to the following formula:

  • Pd = kt*kh*kn
  • Pd - admissible output power
  • kt - correction quotient referring to the influence of cooling air
  • kh - correction quotient referring to the altitude
  • kn - the output power indicated on the name plate.

Correction quotients are defined by Tables 1 and 2:


Table1

t [°C] 40 45 50 55 60
kt [-] 1.00 0.95 0.90 0.83 0.76

Table2

h [m] 1000 1500 2000 2400 3000 3500 4000 4300
Kh [-] 1.00 0.98 0.95 0.93 0.88 0.84 0.80 0.74


Rotation toroque

The output rotation torque of the execution of the driving shaft end of motor is calculated by the following formula:

Mn[W] = 9,55*Pn/nn [N*m]

  • Mn[Nm] - rated torque
  • Pn [W] - rated power
  • nn[min ~1 ] - output rotation speed
  • Ms - starting torque
  • Mmin - minimal torque
  • Mmax - maximal torque
  • ns - synchronic rotation speed

Bearings

Standard sizes of bearings used are given in Table 4.


Table 4 - Standart size of bearings

Frame 63 71 80 90 100 100K 112 132  160 160K 180
Bearings 6201 2RS 6202 2RS 6204 2RS 6205 2RS 6206 2RS 6206 2RS 6308 2RS 6309 2RS 6310 2RS

Vibration value is 1.12 mm/sec, for three-phase motors with over­all dimensions of 63 and 80 mm and 1.8 mm/sec, for motors with overall dimensions 90...160 mm., for single-phase motors dimen­sions — 2.8 mm/sec.

Average value of noise level measured at motor idle rotation does not exceed values given in Table 6.

Note: Values in denominator are given for motors with greater power.


Degree of protection

The degree of protection of the electric motors is IP54 or IP55 according to IEC 60034-5.


Driveng shaft end

The dimensions of the driving shaft end are indicated in the Table 10, (Fig. 2) of overall and joining dimensions.

Shaft driving end has a tapped hole (Table 3), (Fig. 2).

Frame 63 71 80 90 100
100K
112 132 160
A-A B-B
Diametr, mm M4 M5 M6 M8 M10 M12 M10 M16
Lengt, mm 12 10 10 16 19 22 28 22 36

Values of permissible radial and axial loads on the driving shaft are given in Table 5, where the middle of the shaft end is accepted as application point.

THERMAL RESISTANCE CLASS OF INSULATION - F (100 °C) 373K


Standart execution

Height of rotation axis 63 + 100 mm.

The housing is made of aluminium with horizontal and vertical ribs. One ground connection on the housing is provided for usage in moderate climate and two — in tropic climate.

Electric motors with heights of rotation axis 100 +160 ìì — can be mode of cast-iron shields.

Steel bushing is used under the bearing in aluminium shields.

Terminal box is caste as an integral part of the housing and pro­vided with a cover.

Stator winding is impregnated on a vacuum plant.

Overall dimensions and motor dimensions for installation and con­nection are given on Fig. 2 and in Table 10.

Technical data for single-speed three-phase motors are given in Table 7, for multispeed three-phase motors — in Table 8 and for single-phase motors — in Table 9 where:

  • Ip/ln — starting to nominal current ratio;
  • Tmax/Òí — max to nominal torque ratio;
  • Tp/Tn — starting to nominal torque ratio;
  • Cos(f)— power factor;
  • Co — operating capacitor

Motors are painted into the following main colours:

grey — RAL 7012, blue — RAL 5010, black — RAL 9017.


Supply voltage and frequncy

The electric motors are offered with the following supply voltage and frequency:

  • single-phase 230V/50 Hz
  • three-phase 400 V- Y-50 Hz, 400 V- Ä-50 Hz

The rated output and the rotation speed are 20% higher at frequency 60Hz than the same parameters at the frequency 50Hz.


Specihicexec executions

Motors - tropic operations;

Motors with degree of protection IP 55;

Motors with duty cycle S2, S3, S4;

Built-in Motors. The inside rotor diameter (d) and the outside stator diameter (D) are given in Table 11.


Table 11 - The inside rotor diameter (d) and the outside stator diameter (D)

Frame 63 71 80 90 100 112 132 160
d, mm 16 20 25 30 35 36.5 46 54
D, mm 89 100 116 131 149 168 191 225

Motors with attached electromagnetic brake of "TEMPORITI" Com­pany (Italy) and analogues.

Motors with specific technical dimensions.

Our contact details:

212649, Republic of Belarus,
Mogilev, 8 Korolev str.,
JSC «Mogilevsky zavod
«Electrodvigatel»

Chief of the marketing department:
Telefax: (+375 222) 26-37-58

Telefax for orders:
26-36-22, 26-46-53, 26-31-92

E-mail(enterprise):
eldvig@mogilev.by,
E-mail(marketing department):
elmotorbkm@mail.ru

Telex: 102133 WOLNA BY